Level relay-sensors ROS 301

Level relay-sensors ROS 301 of the conductometric principle of operation provide reliable control from one to three levels of electrically conductive liquid in one or more containers, including in explosive zones.

 

Level relay-sensors ROS 301 are installed in automatic process control systems, in alarm systems of limit and emergency liquid levels in tanks for various purposes, in automation and control devices.

 

Relay-sensors meet the requirements of the Rules of the Russian Maritime Register of Shipping and the Russian River Register for signaling devices, measurement and control of non-electrical quantities for vessels with an unrestricted area of navigation. Relay-sensors have versions designed for the use at nuclear energy facilities (hereinafter referred to as NF), including at nuclear power plants (NPP).

 

Depending on the design of the sensing element, the insulator material, the maximum operating pressure, the operating temperature range and method for attaching, the relay sensors have the versions presented in table:

Denomination Operating pressure MPa,

no more than

Operating temperature range, °С Insulator material Method for attaching Design of the sensitive element
Version 1 1,6 from minus 100
to plus 150
Fluoroplastic -40LD Fitting М20х1,5 Rigid
Version 1g Flexible
Version 2 2,5 from minus 100
to plus 250
Fluoroplastic – 4 Rigid
Version 2g Flexible
Version 7 6,3 Fitting М27х1,5 Rigid
Number of sensors connected to one secondary converter
from 1 to 3
Deviation of the trigger level from the lower cut of the electrode
not more than ± 2 mm
Operating ambient temperature
from -50 to +70 °C
Output signal of secondary converters
relay
Power supply parameters of the secondary converter
- DC voltage: 24 V;
- AC voltage: 220 V (50, 60 or 400 Hz)
Degree of protection of the housing
- degree of protection of the housing- sensors: IP67;
- secondary converters: IP54, IP67; IP40 (on DN rail)
Communication line length
no more than 400 m
Assigned service life
15 years without resource restriction
Safety class, when delivered to the NF
3, 4 according to NP-001-15 or NP-022-17

A set of relay-sensor supply must correspond to the configuration specified in table:

Denomination Designation Quantity Note
Sensor According to the order from 1 to 3 pcs.

 

Sensor versions and their quantity are specified by order
Secondary transducer According to the order 1 pcs. Sensor versions is specified by order
Signal cable According to the order from 1 to 3 Supply is specified by order
Passport AGTS.407721.001 PS 1 pcs.
Instruction manual AGTS.407721.001 RE 1 copy for 50 relay-sensors One copy of the instruction manual is attached to the smaller consignment

 

Mounting parts can be included on order (welded bushings, counter-flanges, pipeline segments with sensors installed by the manufacturer), gaskets, transition joints and other elements in the supply package.

Separate supply of components of relay-sensors is allowed.

When ordering relay-sensors for one facility, it is allowed to combine the same type of components or specify their order specifications separately.